Expand description
ИВКЭ record journals (СТО 34.01-5.1-013-2023, §10.10 and §10.11).
- The object-correction journal (§10.10,
0.0.94.7.136.255) records the last correction time of the ИВКЭ configuration objects. - The numeric meter journal (§10.11,
0.0.94.7.137.255) holds meter readings disaggregated one value per row.
Both are ProfileGeneric (IC 7, v1) objects.
Modules§
- transmission_
status transmission statusvalues of an incoming-event row (§8.5.10, Table 4).
Structs§
- Correction
Journal - The object-correction journal (§10.10).
- Correction
Record - One object-correction record (§10.10, Table 9).
- Incoming
Event - One incoming push-event row (§8.5.10, Table 4).
- Incoming
Events Table - The incoming push-events table (§8.5.10,
0.0.94.7.140.255). - Numeric
Journal - The numeric meter journal (§10.11).
- Numeric
Record - One numeric-journal record (§10.11, Table 10). A single disaggregated meter reading with the metadata needed to relate it to its source journal row.