Skip to main content

Module records

Module records 

Source
Expand description

ИВКЭ record journals (СТО 34.01-5.1-013-2023, §10.10 and §10.11).

  • The object-correction journal (§10.10, 0.0.94.7.136.255) records the last correction time of the ИВКЭ configuration objects.
  • The numeric meter journal (§10.11, 0.0.94.7.137.255) holds meter readings disaggregated one value per row.

Both are ProfileGeneric (IC 7, v1) objects.

Modules§

transmission_status
transmission status values of an incoming-event row (§8.5.10, Table 4).

Structs§

CorrectionJournal
The object-correction journal (§10.10).
CorrectionRecord
One object-correction record (§10.10, Table 9).
IncomingEvent
One incoming push-event row (§8.5.10, Table 4).
IncomingEventsTable
The incoming push-events table (§8.5.10, 0.0.94.7.140.255).
NumericJournal
The numeric meter journal (§10.11).
NumericRecord
One numeric-journal record (§10.11, Table 10). A single disaggregated meter reading with the metadata needed to relate it to its source journal row.